S-150W
Kaluaran tunggal: kakuatan 150W
tegangan input: 90 ~ 132VAC / 180 ~ 264VAC ku switch
Modél Spésifikasi | S-150-5 | S-150-12 | S-150-15 | S-150-24 | S-150-36 | S-150-48 |
tegangan kaluaran DC, ayeuna | 5V 0~30A | 12V0 ~ 12.5A | 15V0 ~ 10A | 24V0~6.5A | 36V0~4.1A | 48V0~3.1A |
Gelombang jeung ribut | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
Stabilitas kawat inlet | ± 0,5% | ± 0,3% | ± 0,3% | ± 0,2% | ± 0,2% | ± 0,2% |
stabilitas beban | ± 0,8% | ± 0,3% | ± 0,3% | ± 0,2% | ± 0,2% | ± 0,2% |
Efisiensi | 78% | 82% | 84% | 85% | 86% | 87% |
rentang adjustable pikeun tegangan DC | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% |
rentang tegangan input | 90~132VAC/180~264VAC ku switch 254~370VDC 47~63Hz | |||||
Dampak ayeuna | Tiis mimiti ayeuna 35A / 115VAC 60A / 230VAC | |||||
panyalindungan overload | 105% ~ 150% motong kaluar kaluaran, recovery otomatis | |||||
Overvoltage panyalindungan | 115% ~ 135% Cicing turun tegangan O / P, re-power on cageur | |||||
Setup, gugah, tahan waktos | 100ms, 50ms, 20ms/230VAC dina beban pinuh | |||||
Tahan tegangan | I/PO/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1menit | |||||
lalawanan isolasi | I/PO/P I/P-FG O/PF/G: 500VDC/100MΩ | |||||
Suhu gawé | -10 ℃ ~ + 50 ℃ | |||||
Diménsi | 199 × 110 × 50 mm |
S-200W
Kaluaran tunggal: kakuatan 200W
tegangan input: 180 ~ 264VAC ku switch
Modél Spésifikasi | S-200-5 | S-200-12 | S-200-15 | S-200-24 | S-200-36 | S-200-48 |
tegangan kaluaran DC, ayeuna | 5V 0~40A | 12V0~16A | 15V0~13A | 24V0~8.5A | 36V0~5.5A | 48V0~4.2A |
Gelombang jeung ribut | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p |
Stabilitas kawat inlet | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% |
stabilitas beban | ± 1% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% |
Efisiensi | 79% | 82% | 83% | 83% | 86% | 86% |
rentang adjustable pikeun tegangan DC | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% |
rentang tegangan input | 90 ~ 132VAC / 180 ~ 264VAC | |||||
Dampak ayeuna | Tiis mimiti ayeuna 15A / 115VAC 30A / 230VAC | |||||
panyalindungan overload | 105% ~ 201% motong kaluar kaluaran, recovery otomatis | |||||
Overvoltage panyalindungan | ||||||
Setup, gugah, tahan waktos | 200ms, 50ms, 20ms/230VAC dina beban pinuh | |||||
Tahan tegangan | I/PO/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1menit | |||||
lalawanan isolasi | I/PO/P I/P-FG O/PF/G: 500VDC/100MΩ | |||||
Suhu gawé | -10 ℃ ~ + 50 ℃ | |||||
Diménsi | 199 × 110 × 50 mm |