Tipe | Nguji curren | Waktos tripping | Hasil anu dipiharep | Tipe | Uji ayeuna | Waktos tripping | Hasil anu dipiharep |
B, C, D | 1.13 Dina | t≤1h(Dina≤63A) | Teu tripping | B | 3 Dina | t≤0.1s | Teu tripping |
1.13 Dina | t≤2h(Dina>63A) | C | 5ln | t≤0.1s | |||
B, C, D | 1,45 di | t<1h(Dina≤63A) | Ngajanteng | D | 10 ln | t≤0.1s | |
1.45ln | t<2h(Di>63A) | B | 5ln | t<0.1s | Ngajanteng | ||
B, C, D | 2,55 di | 1s | Ngajanteng | C | 10 ln | t<0.1s | |
2,55 ln | 1s | D | 20 ln | t<0.1s |
1. Overload panyalindungan
2. Perlindungan sirkuit pondok
3. Ngadalikeun
4. Dipaké dina wangunan padumukan, wangunan non-padumukan, industri sumber énergi jeung infrastruktur.
5. Numutkeun jinis pelepasan sakedapan digolongkeun kieu: tipe B(3-5)ln, tipe C(5-10)ln, tipe D(10-20)ln
Tipe | Standar | IEC / EN 60898-1 | |
Fitur listrik | Dipeunteun ayeuna Dina | A | 1, 2, 3, 4, 6, 10, 16,20,25,32,40,50, 63 |
Kutub | P | 1, 2, 3,4 | |
tegangan dipeunteun Ue | V | 230/400 | |
tegangan insulasi Ui | V | 500 | |
Frékuénsi dipeunteun | Hz | 50/60 | |
Kapasitas pegatna dipeunteun | A | 4500 | |
Dipeunteun dorongan tahan tegangan (1.2/50)Uimp | V | 4000 | |
Tegangan uji diéléktrik dina ind. Freq.pikeun 1 mnt | kV | 2 | |
Gelar polusi | 2 | ||
Ciri pelepasan termo-magnétik | B, C, D | ||
Fitur mékanis | Kahirupan listrik | t | 6000 |
Kahirupan mékanis | t | 20000 | |
Gelar panyalindungan | IP20 | ||
Suhu rujukan pikeun netepkeun unsur termal | ℃ | 30 | |
Suhu ambient (kalayan rata-rata poean≤35 ℃) | ℃ | -5~+40 | |
Suhu neundeun | ℃ | -25~+70 | |
Pamasangan | Jenis sambungan terminal | kabel / Pin-tipe busbar | |
Ukuran terminal luhur / handap pikeun kabel | mm2 | 25 | |
AWG | 18-3 | ||
Ukuran terminal luhur / handap pikeun busbar | mm2 | 25 | |
AWG | 18-3 | ||
Torsi tightening | N*m | 2 | |
Dina-1bs | 18 | ||
Pamasangan | Dina rel DIN EN 60715 (35mm) ku alat klip gancang | ||
Sambungan | Ti luhur atawa handap |